***If either heater gets more than five degrees hotter than the water turn off the heaters but not the pumps.
 
***If either heater gets more than five degrees hotter than the water turn off the heaters but not the pumps.
 
***After 10 minutes turn off the pumps then siphon both the lines using the procedure above then restart the LabView program.
 
***After 10 minutes turn off the pumps then siphon both the lines using the procedure above then restart the LabView program.
*The temperature should reach 160-162 degrees Fahrenheit before bending starts.
+
*The temperature reading from the thermistor, displayed in "Temperature Degrees Fahrenheit," should reach 155 degrees before bending starts.
 +
**The actual temperature is about 4 degrees higher according to the alcohol thermometer.
    