Changes

Jump to navigation Jump to search
Line 1: Line 1:  
<table align="right" cellpadding="3">
 
<table align="right" cellpadding="3">
 
<tr><td><b>Important Documents</b></td></tr>
 
<tr><td><b>Important Documents</b></td></tr>
<tr><td bgcolor="#e0e0f0">[[media:3DPrinterManual.pdf|3D Printer Manual]]</td></tr>
+
<tr><td bgcolor="#e0e0f0">[https://zeus.phys.uconn.edu/halld/tagger/TAGM-4-2021/Protolabs_quote_6_2GeV_Move.pdf Protolabs Quote &rarr; 6.2 GeV Move]</td></tr>
<tr><td bgcolor="#e0e0f0">[[media:PLA_MSDS.pdf|PLA Filament MSDS]]</td></tr>
+
<tr><td bgcolor="#e0e0f0">[https://zeus.phys.uconn.edu/halld/tagger/TAGM-4-2021/Top_Plate_6_2Gev.dwg Top-Plate<sub>(<i>3D CAD</i>)</sub> &rarr; 6.2 GeV Move]</td></tr>
<tr><td bgcolor="#e0e0f0">[[media:ABS_MSDS.pdf|ABS Filament MSDS]]</td></tr>
+
<tr><td bgcolor="#e0e0f0">[https://zeus.phys.uconn.edu/halld/tagger/TAGM-4-2021/Upstream_Bar_6_2Gev.dwg Upstream Bar<sub>(<i>3D CAD</i>)</sub> &rarr; 6.2 GeV Move]</td></tr>
<tr><td bgcolor="#e0e0f0">[[media:Lab_419_Printer.pdf|UConn EHS 3D Printer Approval]]</td></tr>
+
<tr><td bgcolor="#e0e0f0">[https://zeus.phys.uconn.edu/halld/tagger/TAGM-4-2021/Downstream_Bar_6_2Gev.dwg Downstream Bar<sub>(<i>3D CAD</i>)</sub> &rarr; 6.2 GeV Move]</td></tr>
<tr><td bgcolor="#e0e0f0">[[https://docs.google.com/document/d/1TfcPB16d2L3PRFAXlTW4cL5QBGmv2FN2DODGC_htHYE/edit?usp=sharing | Ben's Logbook]]</td></tr>
+
<tr><td bgcolor="#e0e0f0">[https://zeus.phys.uconn.edu/halld/tagger/TAGM-4-2021/Bundle-Support-4-2021.xlsx TAGM Move Calculation Spreadsheet]</td></tr>
 +
<tr><td bgcolor="#e0e0f0">[https://zeus.phys.uconn.edu/halld/tagger/TAGM-4-2021/TAGM_9_2GeV_Bundle_Rod_Fit.C C++ File &rarr; Fit mounting rod positions]</td></tr>
 +
<tr><td bgcolor="#e0e0f0">[https://zeus.phys.uconn.edu/halld/tagger/TAGM-4-2021/TAGM_Weights.C C++ File &rarr; List of current rod positions fit eqns.]</td></tr>
 
</table>
 
</table>
    +
=Moving the Tagger Microscope Along the Focal Plane=
 +
 +
==Tagger Microscope==
 +
[[Image:TAGM.png|center|thumb|500px|Figure 1: CAD image of the upper and lower enclosures of the Tagger Microscope made during the design phase.]]
 +
 +
<gallery caption="Prior to Installation in the Tagger Hall" widths="450px" heights="450px" class="center">
 +
  TAGM_Front.png|Figure 2: TAGM just prior to installation in the Tagger Hall. The side of the TAGM seen here will face towards the Tagger Magnet.
 +
  TAGM_Back.jpg|Figure 3: TAGM during reassembly just prior to installation in the Tagger Hall. The side of the TAGM seen here will face away from the Tagger Magnet when installed.
 +
</gallery>
 +
 +
 +
[[Image:e-angle_fiber-amp.png|right|thumb|300px|Figure 4: Result of a MC simulation performed to predict the response of adjacent scintillating fiber columns due to fiber axis misalignment with respect to a post-bremsstrahlung electron's path. The solid line represents the response seen by the central fiber, while the dashed lines are the adjacent fibers' response.]]
 +
 +
The tagger microscope (TAGM) consists of six major components: upper enclosure, lower enclosure, optical fibers, electronics, shielding, and darkening shroud. As seen from the CAD image above, Figure 1, the lower enclosure houses the microscope's electronics, while the upper enclosure contains the optical fiber bundle supports (a.k.a. popsicle sticks). The bundle supports are used to align the scintillating fiber (SciFi) longitudinal axis to the incoming electron's path angle as it passes through the tagger magnet's focal plane. The designed angular tolerance, e.g. fiber to electron allowable angular error, is < 0.5<sup>o</sup>. MC simulations were performed to test the effect of various amounts of misalignment between the electron angle and the SciFi axis. Figure 4 shows a plot of one of these simulations with the solid line showing the scintillation response of the central fiber, while the dashed lines are the response for the adjacent fibers. A factor of three separation between adjacent signal amplitudes is achievable when alignment is < 3<sup>o</sup>. In order to achieve optimal alignment, similar to < 0.2<sup>o</sup> that was seen in bench tests, the SciFi end of the optical fibers are affixed to bundle supports (Figure 5) in the upper enclosure, with the light guide potion of the fiber extending down to silicon photomultipliers (SiPMs) located on preamplifier boards (Figure 6) in the lower enclosure.
 +
 +
 +
<gallery caption="The two ends of the optical fibers" widths="300px" heights="300px" class="center">
 +
  Mounting_Test_Popsicle_Stick.jpg|Figure 5: Picture taken during testing phase of a bundle support with mounted fibers. Note that the bundle support does not have its mounting rods installed. These rods are used to secure the bundle support to the parallel railing system located in the upper enclosure.
 +
  SiPM_alignment.png|Figure 6: Image of the preamplifier board and open chimney (light guide holder) before fiber installation. The chimney aligns the 2mm<sup>2</sup> lightguide end to the center of the 3mm<sup>2</sup> active area of the SiPM with only a 0.5mm air gap between the two.
 +
</gallery>
 +
 +
 +
Moving the TAGM to a new energy range not only involves the physical relocation of the microscope and its shielding along the tagger magnet's focal plane, but also requires internal realignment of the fiber, which is the subject of this page. The realignment of the scintillating fibers' longitudinal axes requires all 17 bundle supports to have new, individual crossing angles (&beta; angle) with respect to the focal plane. These angles are derived from a table generated based on a TOSCA map of the post-bremsstrahlung electrons' crossing angles as they pass through the magnet's focal plane. Since the crossing angle changes with energy (e.g. displacement along the focal plane) each bundle support will have a slight "kick" or "tow" from the adjacent bundle support. The tow is typically on the order of 0.1<sup>o</sup>.
 +
 +
Since the bundle supports have varying &beta; angles, the parallel railing system that holds these supports in place are no longer representative of their namesake. That is, the front and rear rails of the parallel railing system are not parallel to each other and have a pitch with respect to one another. Figure 7 is a pictorial explanation of this and shows that for two equal length rails (front & rear), the length of the upstream and downstream alignment bars differ by 0.039 &plusmn; 0.001 in. at a starting photon energy (E<sub>&gamma;</sub>) with a required tow of 0.09<sup>o</sup> between bundle supports. For each individual photon energy range covered by the microscope, or more simply stated for each energy that the microscope starts at, a new pitch for the parallel rails must be determined and three components (upstream alignment bar, downstream alignment bar, and upstream guide plate) unique to that starting energy must be fabricated. For this reason CAD drawings, an Excel spreadsheet, and this wiki page were created to provide the information needed to realign and move the TAGM to any starting photon energy between 11 and 5 GeV. The turnaround time for the machining components is typically five to seven days, while the realignment of fibers will take no more than two days with inexperienced workers.
 +
 +
[[Image:Beta-Angle-Explanation-White.png|center|thumb|1000px|Figure 7: Pictorial representation of the alignment of the front and rear rails of the parallel railing system, which supports and aligns the optical fiber bundle supports along the tagger magnet's focal plane. The red circles represent the locations of the support rods that extend below the bundle supports and are used to secure them to the railings. This representative image was created from a 3D CAD drawing of the microscope which has a precision of &plusmn; 0.001 in.]]
   −
=Moving the Tagger Microscope along the Focal Plane=
   
==Coordinate System==
 
==Coordinate System==
 
There are three coordinate systems often referred to inside the GlueX Tagger Hall. These coordinate systems have origins associated with the Goniometer center (room coordinates), Tagger Magnet center (map coordinates), and the focal plane (FP coordinates). The room coordinate system has the positive z-coordinate along the beam axis with the positive y direction pointing to the ceiling of the tagger hall from the coordinates origin placed at the Goniometer's center, where the beamline radiator is located. Figure 1 shown below, taken from a presentation by Dan Sober, shows the three coordinate systems relative to one another. The map coordinate system (magnetic mapping) places the y-coordinate along the long axis of the magnet with the positive x-axis parallel to the tagger hall floor in the direction of the focal plane. the positive z-axis of the map coordinate system points toward the tagger hall ceiling. When viewed from above the map y-coordinate is offset from the room coordinate z-axis by 6.5 degrees towards the focal plane (clockwise). The focal plane coordinate system places its x-axis along the electron focal plane with zero being at an electron energy equivalent to a photon energy around 11.7 GeV. The positive x-axis points toward increasing electron energy (decreasing photon energy). The positive y-axis of the focal plane coordinate system points towards the tagger magnet and is parallel to the tagger hall floor. This leaves the focal plane positive z-axis pointing towards the tagger hall ceiling.
 
There are three coordinate systems often referred to inside the GlueX Tagger Hall. These coordinate systems have origins associated with the Goniometer center (room coordinates), Tagger Magnet center (map coordinates), and the focal plane (FP coordinates). The room coordinate system has the positive z-coordinate along the beam axis with the positive y direction pointing to the ceiling of the tagger hall from the coordinates origin placed at the Goniometer's center, where the beamline radiator is located. Figure 1 shown below, taken from a presentation by Dan Sober, shows the three coordinate systems relative to one another. The map coordinate system (magnetic mapping) places the y-coordinate along the long axis of the magnet with the positive x-axis parallel to the tagger hall floor in the direction of the focal plane. the positive z-axis of the map coordinate system points toward the tagger hall ceiling. When viewed from above the map y-coordinate is offset from the room coordinate z-axis by 6.5 degrees towards the focal plane (clockwise). The focal plane coordinate system places its x-axis along the electron focal plane with zero being at an electron energy equivalent to a photon energy around 11.7 GeV. The positive x-axis points toward increasing electron energy (decreasing photon energy). The positive y-axis of the focal plane coordinate system points towards the tagger magnet and is parallel to the tagger hall floor. This leaves the focal plane positive z-axis pointing towards the tagger hall ceiling.
 
      
 
      
[[Image:Tagger_Hall_Coord.png|center|thumb|900px|Figure 1: The three coordinate systems often referred to in association with the Tagger Hall. (Image taken from a [https://halldweb.jlab.org/wiki/images/e/e0/TaggerHodoscopeEnergy-1-2017.pdf Dan Sober Presentation])]]
+
[[Image:Tagger_Hall_Coord.png|center|thumb|800px|Figure 8: The three coordinate systems often referred to in association with the Tagger Hall. (Image taken from a [https://halldweb.jlab.org/wiki/images/e/e0/TaggerHodoscopeEnergy-1-2017.pdf Dan Sober Presentation])]]
 +
 
 +
 
 +
In Spring 2017 a [https://halldweb.jlab.org/wiki/images/e/e0/TaggerHodoscopeEnergy-1-2017.pdf survey] of the various beamline components saw a small change in the Tagger Microscope position. The Microscope (upstream center) position derived from this survey is shown below and includes a magnet center shift from previous measurements.
 +
<center>
 +
  <table style="border:1px solid black;" cellspacing="0">
 +
      <tr>
 +
        <td colspan="2">
 +
            <table style="border: thin solid black;" cellspacing="0">
 +
              <tr>
 +
                  <th colspan="2"; style="background-color:rgb(239,222,205)"><span style="background-color:yellow">Spring 2017</span> </th>
 +
              </tr>
 +
              <tr>
 +
                  <th align="center" valign="top"; style="background-color:rgb(239,222,205)" colspan="2">Survey of Tagger Microscope Position</th>
 +
              </tr>
 +
              <tr>
 +
                  <th style="background-color:rgb(239,222,205); font-size:10px" colspan="2"> <em>(Upstream Center)</em> </th>
 +
              </tr>
 +
            </table>
 +
        </td>
 +
      </tr>
 +
      <tr>
 +
        <td align="right" valign="top">X <sub>room</sub> = </td><td align="left" valign="top"> - 1.16666 m</td>
 +
      </tr>
 +
      <tr>
 +
        <td align="right" valign="top">Z <sub>room</sub> = </td><td align="left" valign="top"> 7.41009 m</td>
 +
      </tr>
 +
      <tr>
 +
        <td align="right" valign="top">Angle <sub>room</sub> = </td><td align="left" valign="top"> - 8.05220<sup>o</sup> </td>
 +
      </tr>
 +
  </table>
 +
</center>
 +
 
 +
 
 +
<center>
 +
  <table style="border:1px solid black;" cellspacing="0">
 +
      <tr>
 +
        <td colspan="2">
 +
            <table style="border: thin solid black;" cellspacing="0">
 +
              <tr>
 +
                  <th colspan="2"; align="center" valign="top"; style="background-color:rgb(124,185,232); font-size:13px">Updated 2017 Coordinates</th>
 +
              </tr>
 +
              <tr>
 +
                  <th colspan="2"; style="background-color:rgb(124,185,232); font-size:10px"> <em>(with magnet center shift) </em> </th>
 +
              </tr>
 +
            </table>
 +
        </td>
 +
      </tr>
 +
      <tr>
 +
        <td align="right" valign="top">X<sub>map</sub> = </td><td align="left" valign="top">0.73488 m</td>
 +
      </tr>
 +
      <tr>
 +
        <td align="right" valign="top">Y<sub>map</sub> = </td><td align="left" valign="top">1.22645 m</td>
 +
      </tr>
 +
      <tr>
 +
        <td align="right" valign="top">X<sub>FP</sub> = </td><td align="left" valign="top">3.31245 m</td>
 +
      </tr>
 +
      <tr>
 +
        <td align="right" valign="top">Y<sub>FP</sub> = </td><td align="left" valign="top">-0.00932 m</td>
 +
      </tr>
 +
 
 +
  </table>
 +
</center>
 +
 
 +
 
 +
<center>
 +
  <table style="border:1px solid black;" cellspacing="0">
 +
      <tr>
 +
        <td colspan="2">
 +
            <table style="border: thin solid black;" cellspacing="0">
 +
              <tr>
 +
                  <th colspan="2"; align="center" valign="top"; style="background-color:rgb(244,143,177); font-size:15px">e<sup>-</sup> Focal Plane Crossing</th>
 +
              </tr>
 +
              <tr>
 +
                  <th colspan="2"; align="center" valign="top"; style="background-color:rgb(244,143,177); font-size:11px"><em>(for e<sup>-</sup> that will pass through the</em></th>
 +
              </tr>
 +
              <tr>
 +
                  <th colspan="2"; align="center" valign="top"; style="background-color:rgb(244,143,177); font-size:11px"><em>center of the 1<sup>st</sup> column's face)</em></th>
 +
              </tr>
 +
 
 +
            </table>
 +
        </td>
 +
      </tr>
 +
      <tr>
 +
        <td align="right" valign="top">X<sub>FP</sub> = </td><td align="left" valign="top">3.26198 m</td>
 +
      </tr>
 +
      <tr>
 +
        <td align="right" valign="top">Y<sub>FP</sub> = </td><td align="left" valign="top">0.0 m</td>
 +
      </tr>
 +
      <tr>
 +
        <td align="right" valign="top">E<sub>&gamma;</sub> = </td><td align="left" valign="top">9.201 GeV</td>
 +
      </tr>
 +
      <tr>
 +
        <td align="right" valign="top">&beta; = </td><td align="left" valign="top">12.695<sup>o</sup></td>
 +
      </tr>
 +
 
 +
  </table>
 +
</center>
 +
 
 +
<!--
 +
[[Image:TAGM_New_Coord.png|center|thumb|500px|Figure 9: Results of a Spring 2017 survey. (Image taken from a [https://halldweb.jlab.org/wiki/images/e/e0/TaggerHodoscopeEnergy-1-2017.pdf Dan Sober Presentation])]]
 +
-->
 +
 
 +
==Bundle Support (a.k.a. Popsicle Stick)==
 +
The Tagger Microscope (TAGM) contains 17 optical fiber bundle, each consists of a 5x6 array of 30 fibers for a total of 510 fibers (5 rows, 102 columns). Figure 2 below shows the fiber array as viewed by the electrons passing through the tagger magnet focal plane. Each optical fiber consists of a 2 mm<sup>2</sup> x 2 cm BCF-20 scintillating fiber (SciFi) thermally fused to 2 mm<sup>2</sup> x 165 cm BCF-98 light guide, see Figures 3 & 4. The SciFi end of each fiber is thermally bent into an "S" shape to remove the fiber from the electrons' path soon after passing through the SciFi, see Figure 5. The fiber begins its bend out of the electrons' path after only 4.5 cm. This length provides enough material past the fused joint to minimize strain on the joint resulting from the bend and fiber mounting straps, while also reducing the material in the line-of-fire that could result in backscatter.
 +
 +
[[Image:Fiber_Array.png|center|thumb|1200px|Figure 9: Electron view of the TAGM scintillating fiber array.]]
 +
 
 +
<gallery caption="Transmission of scintillation light" widths="300px" heights="300px" class="center">
 +
  Fiber_lg.jpg|Figure 10: An end view of a 2 mm<sup>2</sup> light guide fiber (BCF-98). A highly polished end such as the one shown here is required on the light guide end that interfaces with the SiPM for maximum light transmission.
 +
  Fiber.png|Figure 11: Image of the mating joint of 2 cm. of scintillating fiber BCF-20 (left) joined to 165 cm. light guide fiber BCF-98 (right). This picture was taken during the prototyping phase when optical epoxy was used to mate the fibers, the current method of joining fibers uses thermal fusing.
 +
</gallery>
 +
 
 +
[[Image:SciFi-on-Popsicle-Stick.png|center|thumb|400px|Figure 12: CAD image of a bundle support (blue) with a mounted 5x6 fiber bundle. The 'S' bend minimizes the amount of fiber in the path of the electrons.]]
 +
 
 +
 
 +
 
 +
<gallery caption="Bundle Support for a 5x6 Array of Fibers" widths="350px" heights="350px" class="center">
 +
  Old-Popsicle-Stick-CAD-iso.png|Figure 13: Side view of a bundle support (a.k.a. popsicle stick).
 +
  Old-Popsicle-Stick-CAD-top.png|Figure 14: Top view of a bundle support (a.k.a. popsicle stick).
 +
  Old-Popsicle-Stick-CAD-iso3.png|Figure 15: Side view of a bundle support (a.k.a. popsicle stick).
 +
</gallery>
 +
 
 +
===<u>Popsicle Stick Limitations</u>===
 +
Placing the "Pivot Point" on the focal plane and only allowing +0.5 cm towards the tagger magnet the maximum crossing angle for the current bundle support design is &beta;<sub>max</sub> = 19.51<sup>o</sup>, while the minimum angle is &beta;<sub>min</sub> = 4.05<sup>o</sup>. This does not account for the most forward bundle mounting strap clamp and bolts, but they are lower in Z<sub>FP</sub> than the fibers and should not extend significantly past the 0.5 cm limit even at lower &beta; angles.
 +
 
 +
==Calculating Position of Each Bundle Support Mounting Rod==
 +
Up to 17 bundle supports can be mounted on the parallel railing system and instrumented in the TAGM. As the range of photon energies being tagged decreases (e.g. electron energy increases) the crossing angle (&beta; angle) of the electrons with the focal plane also decreases. The smaller the &beta; angle the more space along the X<sub>FP</sub> axis a bundle support will occupy. Below an E<sub>&gamma;</sub> of 6.5 GeV (&beta; = 9.5<sup>o</sup>) the length of the parallel railing system can only mount a maximum of 16 bundle supports.
 +
 
 +
Since the &beta; angle changes across the TAGM energy range, a universal bundle support &beta; angle cannot be used. Starting with the most upstream bundle support (e.g. highest energy tagged photons) an initial bundle support angle is selected by taking the average of the crossing angles at the tagger magnet's focal plane for the electrons that pass through the center of the first and sixth fiber columns of that bundle. Recall that each bundle support holds an array of 5x6 fibers split into two 5x3 bundle halves. These halves are offset so that the bundle "pivot point" and the front center of each bundle half will all sit on the focal plane for &beta; = 12<sup>o</sup>. The pivot point is located at the midpoint of the bundle halves' offset and the boundary point of the two bundle halves (e.g. along the bundle support long axis). The long axis, which lies along the bundle support centerline, passes through the pivot point, front mounting rod, and rear mounting rod. This fact is exploited during the calculations to follow. The pivot point is solely determined from the bundle support's design (e.g. offset distance) and is essential for fiber alignment on the focal plane. Regardless of the bundle &beta; angle, if the focal plane passes through the bundle support's pivot point then the SciFi's will be at their optimal location with the magnitude of maximum fiber extension (&plusmn; Y<sub>FP</sub>) being the same.           
 +
 
 +
 
 +
Once the &beta; angle for the first (upstream) bundle support is set, derived from the the starting photon tag energy, each subsequent bundle support has a &beta; angle offset from the previous one by a tow angle. Thus, as we look downstream from one bundle support to the next, the &beta; angles differ by -(tow angle). Adjacent bundle supports will come in contact with one another at the SciFi end and form a triangular gap along their adjacent sides based on the tow angle.
 +
 
 +
An Excel [https://zeus.phys.uconn.edu/halld/tagger/TAGM-4-2021/Bundle-Support-4-2021.xlsx spreadsheet] has been created to calculate the location of the bundle supports' mounting rods with respect to the focal plane coordinate system. This spreadsheet also calculates the length of the parallel railing end supports which need to be fabricated anew for each unique TAGM location on the focal plane. One last, but very important thing that the spreadsheet calculates is the shim size needed, during TAGM realignment, in order to achieve the proper tow angle between bundle supports during mounting. In addition to the spreadsheet, an AutoCAD [https://zeus.phys.uconn.edu/halld/tagger/TAGM-4-2021/Parallel_Railing_Parts.dwg drawing] used to design the three parallel rail components needed for each unique tagging energy spectrum starting position of the TAGM and a [https://zeus.phys.uconn.edu/halld/tagger/TAGM-4-2021/Beta-Angle12_5-to-11_06deg_modified.dwg drawing] for the current setup (&beta; = 12.5<sup>o</sup> to 11.06<sup>o</sup>). These files are in US standard units (inches) and to scale with a tolerance of &plusmn; 0.001 inch. 
 +
 
 +
 
 +
===<u>A summary of the spreadsheet calculations is on the following wiki page:</u>===
 +
 
 +
[https://zeus.phys.uconn.edu/wiki/index.php/Calculating_the_move Calculating the move]
 +
 
 +
 
 +
[[Image:e_path_in_Bundle.png|center|thumb|800px|Figure 16: Sketch showing the path of electrons that pass through the center of the fiber columns near the focal plane. At the back-end of the 2 cm. SciFi a misalignment of around 0.03 mm (with respect the the fiber's axis) results from using an averaged &beta; angle for the bundle support location.]]
 +
 
 +
==TAGM Move Parameters for various E<sub>&gamma;</sub> Starting Points==
 +
Using the calculations explained in [https://zeus.phys.uconn.edu/wiki/index.php/Calculating_the_move "Calculating the move" wiki page], the following parameters for a 6 GeV maximum tagged photon energy were determined.
 +
 
 +
 
 +
<center>
 +
<table border="8" cellspacing="0">
 +
  <tr>
 +
      <td colspan="3">
 +
        <table style="border: thin solid black;" cellspacing="0">
 +
            <tr>
 +
              <td align="left" valign="top">Starting E<sub>&gamma;</sub> = </td> <td align="center" valign="top"> 6.0</td> <td align="left" valign="top"> GeV</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">Ending E<sub>&gamma;</sub> = </td> <td align="center" valign="top"> 4.475</td> <td align="left" valign="top"> GeV</td>
 +
            </tr>
    +
            <tr>
 +
              <td align="left" valign="top">1<sup>st</sup> Bundle &beta;<sub>o</sub> Angle = </td> <td align="center" valign="top"> 9.246</td> <td align="left" valign="top"> degrees</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">1<sup>st</sup> Bundle Resolution = </td> <td align="center" valign="top"> 15.1</td> <td align="left" valign="top"> MeV</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">Last Bundle &beta;<sub>f</sub> Angle = </td> <td align="center" valign="top"> 8.51</td> <td align="left" valign="top"> degrees</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">Last Bundle Resolution = </td> <td align="center" valign="top"> 17.1</td> <td align="left" valign="top"> MeV</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">No. of Bundles Used = </td> <td align="center" valign="top"> 16</td> <td align="left" valign="top">Bundles </td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">Tow Angle = </td> <td align="center" valign="top"> 0.049</td> <td align="left" valign="top"> degrees</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">Tow Shim = </td> <td align="center" valign="top"> 0.0056</td> <td align="left" valign="top"> inches</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">Forward Rail Pitch = </td> <td align="center" valign="top"> 0.035</td> <td align="left" valign="top"> degrees</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">Rear Rail Pitch = </td> <td align="center" valign="top"> 0.118</td> <td align="left" valign="top"> degrees</td>
 +
            </tr>
   −
In Spring 2017 a survey of the various beamline components saw a small change in the Tagger Microscope position. The Microscope (upstream center) position derived from this survey is shown below and includes a magnet center shift from previous measurements.
+
            </table>
 +
        </td>
 +
      </tr>
 +
  </table>
 +
</center>
   −
[[Image:TAGM_New_Coord.png|center|thumb|600px|Figure 2: Results of a Spring 2017 survey. (Image taken from a [https://halldweb.jlab.org/wiki/images/e/e0/TaggerHodoscopeEnergy-1-2017.pdf Dan Sober Presentation])]]
     −
==Next==
  −
xxxxxx
  −
[[Image:Magnetic_Field_Map.pdf|center|thumb|300px|Figure 3: Table of the electrons' positions as they pass through the Focal Plane.]]
     −
xxxxxx
     −
==Final==
+
<center>
xxxxxxxxxxxxx
+
<table border="8" cellspacing="0">
 +
  <tr>
 +
      <td colspan="3">
 +
        <table style="border: thin solid black;" cellspacing="0">
 +
            <tr>
 +
              <td align="left" valign="top">Starting E<sub>&gamma;</sub> = </td> <td align="center" valign="top"> 6.2</td> <td align="left" valign="top"> GeV</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">Ending E<sub>&gamma;</sub> = </td> <td align="center" valign="top"> 4.703</td> <td align="left" valign="top"> GeV</td>
 +
            </tr>
    +
            <tr>
 +
              <td align="left" valign="top">1<sup>st</sup> Bundle &beta;<sub>o</sub> Angle = </td> <td align="center" valign="top"> 9.364</td> <td align="left" valign="top"> degrees</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">1<sup>st</sup> Bundle Resolution = </td> <td align="center" valign="top"> 14.7</td> <td align="left" valign="top"> MeV</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">Last Bundle &beta;<sub>f</sub> Angle = </td> <td align="center" valign="top"> 8.605</td> <td align="left" valign="top"> degrees</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">Last Bundle Resolution = </td> <td align="center" valign="top"> 16.8</td> <td align="left" valign="top"> MeV</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">No. of Bundles Used = </td> <td align="center" valign="top"> 16</td> <td align="left" valign="top">Bundles </td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">Tow Angle = </td> <td align="center" valign="top"> 0.051</td> <td align="left" valign="top"> degrees</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">Tow Shim = </td> <td align="center" valign="top"> 0.0058</td> <td align="left" valign="top"> inches</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">Forward Rail Pitch = </td> <td align="center" valign="top"> 0.036</td> <td align="left" valign="top"> degrees</td>
 +
            </tr>
 +
            <tr>
 +
              <td align="left" valign="top">Rear Rail Pitch = </td> <td align="center" valign="top"> 0.123</td> <td align="left" valign="top"> degrees</td>
 +
            </tr>
   −
*[http://zeus.phys.uconn.edu/~pratt/software/ablator.C '''AAAA.C: Text here.''']
+
            </table>
 +
        </td>
 +
      </tr>
 +
  </table>
 +
</center>
581

edits

Navigation menu