*[https://docs.google.com/a/uconn.edu/document/d/1mGxw-1p69iodf4hJz1tTTfBxgvfdGpDbZynqvXzYCLc/edit# Liana's Work Journal] and [http://zeus.phys.uconn.edu/wiki/index.php/LH_Summer_2014 Liana's Summer Wiki Page] accompany her Troubleshooting tests which describes more in-depth the thought process and steps behind each run.
*[https://docs.google.com/a/uconn.edu/document/d/1mGxw-1p69iodf4hJz1tTTfBxgvfdGpDbZynqvXzYCLc/edit# Liana's Work Journal] and [http://zeus.phys.uconn.edu/wiki/index.php/LH_Summer_2014 Liana's Summer Wiki Page] accompany her Troubleshooting tests which describes more in-depth the thought process and steps behind each run.
+
+
+
==Previous Procedures==
+
*Metal clamps and wires were previously used to secure the bundles of 15 to the fibers' popsicle sticks. We then graduated to using only one metal clamp over two 15-fiber bundles and two kapton strips per popsicle stick.
+
[[File:LH-FiberTesting-PopStickClamp.jpg|thumb|center|upright|The popsicle stick with clamp and wires to hold the fibers in place.]]
+
*We are currently working on making the paper spacings procedure easier.
+
[[File:LH-FiberTesting-PaperSpacers.jpg|thumb|center|upright|A view of 15 flush fibers separated with paper spacers between each row and column.]]
+
+
*The following photos were taken before the pulser circuit was fixed (added around June 16th) and before the pulser ran on a power supply. The pulser was modified to run on a power supply on July 3rd, 2014. You can see the results of this change on the "Scramble on Power Supply" page of the [https://docs.google.com/a/uconn.edu/spreadsheets/d/1SNiHFm5fo_8yHHBrvuciXn_IRJ8aHT6QC_DbKERF3K0/edit#gid=101819727 Fiber QA Troubleshooting Google Doc]
+
{|style="margin: 0 auto;"
+
| [[File:LH-FiberTesting-Pulsar1.jpg|thumb|center|upright|Image of the fibers, mirror and pulsar from the main opening of the dark box.]]
+
| [[File:LH-FiberTesting-Pulsar2.jpg|thumb|center|upright|Image of the fibers, mirror and pulsar from along the fibers.]]
+
|[[File:LH-FiberTesting-InsideDarkBox.jpg|thumb|center|upright|View of the fibers from the main opening of the dark box. Black plastic separates the scintillating fiber end and pulsar from the chimneys and SciPMs.]]
+
|}