Line 36: |
Line 36: |
| * Hold the spool end of the fiber in place with your left hand. | | * Hold the spool end of the fiber in place with your left hand. |
| * Cut the fiber along the notch with the Dremel. | | * Cut the fiber along the notch with the Dremel. |
| + | |
| + | {|style="margin: 0 auto;" |
| + | |[[File:JK Cut Mark.JPG|thumb|upright|The station used to measure and then cut the scintillating fibers. The lightguide station is an extended version of this.]] |
| + | |[[File:JK Lightguide Cutting Station.JPG|thumb|upright|The lightguide cutting station and weight used to hold down fibers.]] |
| + | |} |
| + | |
| * Turn off the Dremel and set it aside. | | * Turn off the Dremel and set it aside. |
| * Ensure that the clip has the fiber firmly secured in place before letting go of the fiber. | | * Ensure that the clip has the fiber firmly secured in place before letting go of the fiber. |
Line 45: |
Line 51: |
| ** For SciFi: only one measurement at the center of the 3 cm fiber is required. | | ** For SciFi: only one measurement at the center of the 3 cm fiber is required. |
| ** For light guide: align the fiber to the marks indicated on the wood guide and take the required measurements at the points designated by the markings. | | ** For light guide: align the fiber to the marks indicated on the wood guide and take the required measurements at the points designated by the markings. |
| + | [[File:JK Micrometer.JPG|thumb|upright|The micrometer used to take the cross-sectional dimensions of the fibers.]] |
| * Visually inspect the fiber for damage, paying particular attention to possible | | * Visually inspect the fiber for damage, paying particular attention to possible |
| ** Cracks | | ** Cracks |
| ** Cladding flare. | | ** Cladding flare. |
| * If the fiber passes the dimensional limits stated in the specifications document and the visual inspection, place it in the storage box. | | * If the fiber passes the dimensional limits stated in the specifications document and the visual inspection, place it in the storage box. |
| + | [[File:JK Intermediate Dark Box.JPG|thumb|upright|Fibers in various stages of production are stored in the intermediate dark box.]] |
| * Fibers that do not pass dimensional inspection are either discarded or kept in a separate location, with non-compliant areas marked with painters' tape. | | * Fibers that do not pass dimensional inspection are either discarded or kept in a separate location, with non-compliant areas marked with painters' tape. |