[[Image:HPD_OnePEdist.png|thumb|300px|Distributions of primary and secondary photoelectron signals (noise included) for one incident primary photoelectron.]]
 
[[Image:HPD_OnePEdist.png|thumb|300px|Distributions of primary and secondary photoelectron signals (noise included) for one incident primary photoelectron.]]
 +
 +
 +
Fixed parameters from HPD specifications and no-light distribution ("pedestal") measurement:
 +
* Total gain, including amplifier and oscilloscope waveform mean rescaling: 1.9264&nbsp;&times;&nbsp;10<sup>5</sup>&nbsp;V/p.e.;
 +
* Pedestal position: -3.6606&nbsp;&times;&nbsp;10<sup>-3</sup>&nbsp;V;
 +
 +
{| style="text-align:center" border="1" cellspacing="0" cellpadding="5"
 +
|-
 +
! colspan="2"| Gaussian 1 
 +
! colspan="2"| Gaussian 2
 +
|-
 +
| p                  || 107.3  || r      || 115.2
 +
|-
 +
| &alpha;            || .000815 || &beta; ||.000524
 +
|-
 +
| &sigma;<sub>2</sub> || 35.01  || &sigma;<sub>3</sub> || 132.9
 +
|-
 +
|}