==Procedural Corrections - 8/30/2018==
 +
 +
The fibers are too dirty. So are the popsicle stick, the alignment jig, and the desk we use to align the fibers. The SiPMs might be dirty too. Now I need to clean everything.
 +
 +
Our alignment should be improved. If a straight edge is held against the end of the popsicle stick, the fibers in positions 16 to 30 should be touching it. If the straight edge is against the end of the part under positions 1 to 15, the fibers should be touching that too.
 +
 +
The straps should not be projecting beyond the end of the bundle. Also, if the clamp sticks out, it could damage the alignment jig.
 +
 