Changes

Jump to navigation Jump to search
Line 23: Line 23:     
==Laser Beamline==
 
==Laser Beamline==
Figure 1 illustrates the arrangement of the ablation set up. A series of quartz plates are positioned immediately in front of the laser aperture so that a small sample of the beam (<5%) is reflected onto two separate energy meters labeled energy meter 1 and energy meter 2. Energy meter 1 is part of the laser’s on board energy feedback system which is used to control the output energy and stabilize the pulse-to-pulse variation to within 5%. Energy meter 2 measures each laser pulse incident on the diamond target during the ablation process.
+
[[Image:ablation_full.png|center|thumb|500px|Rendering of ablation beamline]]
[[Image:ablation_full.png|center|thumb|500px|Rendering of ablation beamline]]
+
Figure 1 illustrates the arrangement of the ablation set up. A series of quartz plates are positioned immediately in front of the laser aperture so that a small sample of the beam (<5%) is reflected onto two separate energy meters labeled energy meter 1 and energy meter 2. Energy meter 1 is part of the laser’s on board energy feedback system which is used to control the output energy and stabilize the pulse-to-pulse variation to within 5%. Energy meter 2 measures each laser pulse incident on the diamond target during the ablation process.  
 
[[Image:spherabs.png|center|thumb|300px|Zygo image of pulses made on diamond after passing through a single focusing lens.]]  
 
[[Image:spherabs.png|center|thumb|300px|Zygo image of pulses made on diamond after passing through a single focusing lens.]]  
 
Figure 5a shows two columns of broad asymmetric patterns in a diamond sample cut using only a single lens for a varying number of laser pulses. If the focal spot that created these patterns was rastered over an entire diamond it would result in a radiator with large surface variations rendering it unusable for GlueX.[[Image:goodfocus.png|center|thumb|300px|Zygo image of pulses made on diamond after passing through the three lens system.]]
 
Figure 5a shows two columns of broad asymmetric patterns in a diamond sample cut using only a single lens for a varying number of laser pulses. If the focal spot that created these patterns was rastered over an entire diamond it would result in a radiator with large surface variations rendering it unusable for GlueX.[[Image:goodfocus.png|center|thumb|300px|Zygo image of pulses made on diamond after passing through the three lens system.]]
581

edits

Navigation menu