Changes

Jump to navigation Jump to search
m
no edit summary
Line 4: Line 4:       −
= Project Branches =
+
== R&D Branches ==
   −
== R&D into Fiber-Array Fabrication Techniques ==
+
=== R&D into Fiber-Array Fabrication Techniques ===
    
[[Image:TaggerFocalPlane_ChannelPlan.png|thumb|555px|Scintillating fiber channels as seen by an on-coming electron. Since only energy tagging is required, the members of the 5-channel columns are summed to produce one signal corresponding to that energy channel. The exceptional columns are marked in red - the signals from their individual fibers will be read out to ascertain focal plane orientation and vertical spread. Note the segmentation of the 100-energy bin (column) array into 20 fiber modules. This is thought to be a more manageable design, corresponding nicely to the photo-sensor/electronics grouping.]]
 
[[Image:TaggerFocalPlane_ChannelPlan.png|thumb|555px|Scintillating fiber channels as seen by an on-coming electron. Since only energy tagging is required, the members of the 5-channel columns are summed to produce one signal corresponding to that energy channel. The exceptional columns are marked in red - the signals from their individual fibers will be read out to ascertain focal plane orientation and vertical spread. Note the segmentation of the 100-energy bin (column) array into 20 fiber modules. This is thought to be a more manageable design, corresponding nicely to the photo-sensor/electronics grouping.]]
Line 17: Line 17:       −
== Scintillation Detection Sensors ==
+
=== Scintillation Detection Sensors ===
    
[[Image:SSPM06_(2x2).jpg|thumb|113px|4.4&nbsp;mm<sup>2</sup> active area Silicon Photomultiplier]]
 
[[Image:SSPM06_(2x2).jpg|thumb|113px|4.4&nbsp;mm<sup>2</sup> active area Silicon Photomultiplier]]
Line 26: Line 26:       −
== Photo-Sensor Support Electronics ==
+
=== Photo-Sensor Support Electronics ===
    
:''Main article: [[Design and prototyping of SiPM electronics]]''
 
:''Main article: [[Design and prototyping of SiPM electronics]]''
Line 33: Line 33:       −
== Mechanical Design of the Tagger Microscope ==
+
=== Mechanical Design of the Tagger Microscope ===
    
:''Main article: [[Tagger Microscope Mechanical Design]]'' ([[User:Senderovich|Igor Senderovich]], James McIntyre]]
 
:''Main article: [[Tagger Microscope Mechanical Design]]'' ([[User:Senderovich|Igor Senderovich]], James McIntyre]]
Line 41: Line 41:        +
== Beam Test in Hall B at Jefferson Lab ==
   −
[[User:Senderovich|Igor Senderovich]] 19:50, 15 December 2009 (UTC)
+
Preparations for testing the tagger microscope in a live beam are underway. The ideal place to test the prototype is near another tagger magnet such as the one in Hall B. Thus the plan is to set the prototype downstream of Hall B's hodoscope. 
 +
 
 +
 
 +
[[User:Senderovich|Igor Senderovich]] 21:31, 22 March 2010 (UTC)
1,004

edits

Navigation menu