We are currently in production of 12 additional fiber bundles to replace the low-performing bundles from the last production run. Current progress is being kept in the [https://docs.google.com/a/uconn.edu/spreadsheets/d/1AZPVzbwDgBWl5UXUVSnz_8_0yO6rmNUTt_MeylHasTQ/ Fibers - 2015 Google Spreadsheet].
+
==Summer 2017==
 +
This summer, I (Micah Warren) am constructing seven new bundles to replace old ones in the tagger microscope. The following pages provide documentation:
 +
 
 +
[[Rough Cut Documentation Summer 2017]]
 +
 
 +
[[Pockmark Documentation Summer 2017]]
 +
 
 +
==2015 and Earlier==
 +
We are currently in production of 12 additional fiber bundles to replace bundles which are currently installed in the microscope. We found that our light guide fibers were not double clad, but were only single clad. In August and September of 2014, we received a new order of BCF-98 and BCF-20 which we verified as multi-clad using [[Cladding Images|EDX techniques]]. In addition to having a second cladding layer, we are also attempting to maintain the optical qualities best by minimizing strain on fibers by removing some of the fiber procedures.  
 +
 
 +
Current progress is being kept in the [https://docs.google.com/a/uconn.edu/spreadsheets/d/1AZPVzbwDgBWl5UXUVSnz_8_0yO6rmNUTt_MeylHasTQ/ Fibers - 2015 Google Spreadsheet].
    
=Procedures for Tagger Microscope Construction=
 
=Procedures for Tagger Microscope Construction=
 +
 +
Here is a master document which describes the procedures: [https://docs.google.com/document/d/15OreBfdhb5mdpdXz6KMTVQt8ZWMU-4OV9i8Y6vp97Ms/edit# Construction Plan for the Tagger Microscope]
    
[[Fiber Rough Cut Procedure]]
 
[[Fiber Rough Cut Procedure]]
   −
[[Straightening Light Guides Procedure]]<i> Discontinued Jan 2015</i>
+
[[Fiber Numbering Procedure]]
 +
 
 +
[[Fiber Measuring Procedure]]
   −
[[Fiber Cleaning Procedure]] <i> Discontinued Summer 2014 </i>
+
[[Fiber Bundling Procedure]]
   −
[[End Milling Procedure]]
+
[[End Milling Procedure]] <i> Discontinued Summer 2017 </i>
    
[[Fiber Polishing Procedure]]
 
[[Fiber Polishing Procedure]]
Line 16: Line 30:  
[[Fiber Fusing Procedure]]
 
[[Fiber Fusing Procedure]]
   −
[[Fiber Bending Procedure]] <i> Discontinued Jan 2015 </i>
+
[[Temperature Control Program|Hot Air Bending Procedure]]
 +
 
 +
[[Fiber Testing Procedure]]
 +
 
 +
[[Hot Water Straightening Light Guides Procedure]]<i> Discontinued Jan 2015</i>
 +
 
 +
[[Fiber Water Stain Cleaning Procedure]] <i> Discontinued Summer 2014 </i>
 +
 
 +
[[Hot Water Fiber Bending Procedure]] <i> Discontinued Jan 2015 </i>
    
[[Fiber Painting Procedure]]<i> Discontinued May 2014 </i>
 
[[Fiber Painting Procedure]]<i> Discontinued May 2014 </i>
    
Fiber Gluing Procedure <i> Discontinued Spring 2014 </i>
 
Fiber Gluing Procedure <i> Discontinued Spring 2014 </i>
  −
[[Fiber Testing Procedure]]
      
=A List of Specifications/Manuals for Items in Lab 405=
 
=A List of Specifications/Manuals for Items in Lab 405=
Line 28: Line 48:  
This page has the documentation for the various procedures and pieces of equipment that are used in the bending tank, the splicing unit, and elsewhere in 405.
 
This page has the documentation for the various procedures and pieces of equipment that are used in the bending tank, the splicing unit, and elsewhere in 405.
 
[[Documents for 405]]
 
[[Documents for 405]]
 +
 +
 +
=Fiber Statistics=
 +
 +
[[Fiber Dimension Statistics]]
 +
    
=Miscellaneous Fiber Testing=
 
=Miscellaneous Fiber Testing=
Line 54: Line 80:  
Fiber transmission measurements were carried out in Lab 402 using a flash ADC and a VME-based data acquisition system that was loaned to UConn by Jefferson Lab.  Our contact at Jlab for this system is Alex Somov.  Setup and operation of the CODA data acquisition platform is described [[Data Acquisition using CODA|here]].
 
Fiber transmission measurements were carried out in Lab 402 using a flash ADC and a VME-based data acquisition system that was loaned to UConn by Jefferson Lab.  Our contact at Jlab for this system is Alex Somov.  Setup and operation of the CODA data acquisition platform is described [[Data Acquisition using CODA|here]].
 
*[[Description and Layout of the VME Data Acquisition Setup]]
 
*[[Description and Layout of the VME Data Acquisition Setup]]
*[[Procedure for Operation of CODA Run Control]]
+
*[[Procedure for Operation of CODA Run Control - Fall 2013]]
 
*[[Creating/Editing mSQL Databases for CODA]]
 
*[[Creating/Editing mSQL Databases for CODA]]
 
*[http://halldweb1.jlab.org/wiki/index.php/Private:UConn_test_setup Alex Somov's instructions for running the CODA-based DAQ]
 
*[http://halldweb1.jlab.org/wiki/index.php/Private:UConn_test_setup Alex Somov's instructions for running the CODA-based DAQ]
*[[media:Jlab_VME_discriminator_manual.pdf|VME discriminator manual]]
+
*[[media:Jlab_VME_discriminatorRevD_manual.pdf|VME discriminator manual]]
*[[media:FADC250UsersManual.pdf|VME FADC250 manual]]
+
*[[media:FADC250UsersManual.pdf|VME FADC250 manual]] ([[media:FADC250_V2_ADC_FPGA_V90E.pdf|firmware update 90E]], [[media:FADC250_Processing_FPGA_Firmware_ver_0x0C01.pdf|firmware update C01]])
*[[media:Jlab_F1_TDC_manual.pdf|VME F1TDC manual]]
+
*[[media:Jlab_F1_TDC_manual.pdf|VME F1TDC manual]] ([[media:F1TDC_V2_V3_8_26.pdf|latest firmware update]])
 +
*[[media:CaenADCv792_rev18.pdf|Caen QDC v792 manual]]
 +
*[[media:TI-old-VME.pdf|VME Trigger Interface (old-style VME) manual]]
 +
*[[media:TI-new-VXS.pdf|VXS Trigger Interface (new-style VXS) manual]]
 +
*[[Operation of CODA Run Control - Fall 2015]]
 
*[http://zeus.phys.uconn.edu/halld/tagger/fp-microscope/fiberQA-2-2014/analyzer Analyzer] - software package that extracts pulse information from CODA data files and stores them in a root tree.
 
*[http://zeus.phys.uconn.edu/halld/tagger/fp-microscope/fiberQA-2-2014/analyzer Analyzer] - software package that extracts pulse information from CODA data files and stores them in a root tree.
 +
 +
=Hot Air Bending Box=
 +
After our experience with with heating fibers in water for straightening and bending, we decided to change our procedure and use hot air instead of water. The following pages show information about the heating box and the program used to run it.
 +
 +
[[Fiber Heating Box]]<br/>
 +
[[Temperature Control Program]]
 +
 +
=Intermediate Storage Box=
 +
[[Intermediate Storage Box]]
    
=Lab Journals / Research Progress=
 
=Lab Journals / Research Progress=
Line 112: Line 151:     
[[Map of Lab 405]]
 
[[Map of Lab 405]]
 +
[Out of date as of 6/19/17]