Changes

Jump to navigation Jump to search
211 bytes removed ,  14:37, 26 June 2018
no edit summary
Line 62: Line 62:  
|}
 
|}
   −
* Hold the light guide in place while hitting the "START" button to the right. After the automated fusing process clamps the top ferrule to the bottom ferrule, push the top ferrule down to make sure it is in contact with the bottom ferrule. Give the light guide a push to the right to make sure it is firmly in contact with the Sci-Fi.
+
* Hold the light guide in place while hitting the "START" button to the right. After the automated fusing process clamps the top ferrule to the bottom ferrule, push down on the metal above the top ferrule to make sure the top ferrule is in contact with the bottom ferrule. Give the light guide a push to the right to make sure it is firmly in contact with the Sci-Fi.
   −
[[File:splicing gasket clamp check.JPG|thumb|center|The properly seated lightguide to look for. Note that the clamp will not slide to the right as shown until the lamp comes on, so only check for the seating of the LG before lowering the protective screen.]]
+
[[File:splicing gasket clamp check.JPG|thumb|center|The properly seated lightguide to look for. Note that the clamp will not slide to the right as shown until just before the lamp comes on, so only check for the seating of the LG before lowering the protective screen.]]
    
* In the few seconds between when the collars clamp together and the light turns on, check the following:
 
* In the few seconds between when the collars clamp together and the light turns on, check the following:
Line 81: Line 81:     
* After the fusing process is complete, the ferrules will become unclamped. Carefully remove the fused fibers and inspect the fuse joint. If the fibers do not appear to be completely fused, if there is a significant dimple in the fuse, or if there are air bubbles in the fuse joint, notify the lead technician.
 
* After the fusing process is complete, the ferrules will become unclamped. Carefully remove the fused fibers and inspect the fuse joint. If the fibers do not appear to be completely fused, if there is a significant dimple in the fuse, or if there are air bubbles in the fuse joint, notify the lead technician.
  −
* There will usually be a slight protrusion in the fiber where the ferrules meet due to flow in the melting plastic, however this is small and can be filed off with minimal damage to the cladding by carefully sanding only on the corners of the fuse site.
      
* If the fibers appear fused, measure and record both cross-sections of the fuse joint. Complete the fusing process for 30 fibers to complete a bundle.
 
* If the fibers appear fused, measure and record both cross-sections of the fuse joint. Complete the fusing process for 30 fibers to complete a bundle.
Line 88: Line 86:  
{|style="margin: 0 auto;"
 
{|style="margin: 0 auto;"
 
| [[File:splicing fuse lip.JPG|thumb|upright|Check the fuse site for small imperfections like this.]]
 
| [[File:splicing fuse lip.JPG|thumb|upright|Check the fuse site for small imperfections like this.]]
| [[File:splicing fuse lip sanding.JPG|thumb|upright|If a lip has formed, sand it off, careful to only sand at at the corner to prevent damage to the optical cladding.]]
+
| [[File:splicing fuse lip sanding.JPG|thumb|upright|If a wing has formed, sand it off, careful to only sand at at the corner to prevent damage to the optical cladding.]]
 
| [[File:Fuse Site.jpg|thumb|upright|A finished fuse between a SciFI and a Lightguide.]]
 
| [[File:Fuse Site.jpg|thumb|upright|A finished fuse between a SciFI and a Lightguide.]]
 
|}
 
|}
1,037

edits

Navigation menu