Line 99:
Line 99:
==Ablation Chamber==
==Ablation Chamber==
−
An aluminum vacuum chamber was machined at UConn to house the diamond during the ablation process as shown in the figure below. A roughing pumps was attached to one of the ports on the ablation chamber while a second port was connected to a digital flow controller and needle valve. This enabled the user to maintain a constant pressure to within 1 mtorr over the course of an ablation run. Vacuum pressures of a few tens of mtorr were achievable using this setup, however were not typically desired due to the large amounts of amorphous carbon build up after ablation occurred.
+
An aluminum vacuum chamber was machined at UConn to house the diamond during the ablation process as shown in the figure below.
+
[[Image:ablationchamber.png|center|300px| CAD drawing of ablation chamber]]
+
A roughing pumps was attached to one of the ports on the ablation chamber while a second port was connected to a digital flow controller and needle valve. This enabled the user to maintain a constant pressure to within 1 mtorr over the course of an ablation run. Vacuum pressures of a few tens of mtorr were achievable using this setup, however were not typically desired due to the large amounts of amorphous carbon build up after ablation occurred.
==XYZ Translation Stages==
==XYZ Translation Stages==