Amplifier board debugging notes
This page contains a list of all currently known problems with the amplifier board and the solutions implemented
Problems
Improper DC levels from voltage regulators
Description
Incorrect voltage levels on the basis of the transistors representing the input stages for base amplifier and summing circuits.
Cause
The pads for pins Gnd and Vz of the voltage regulators were reversed. The proper assignment of pins is shown in the adjacent figure.
Solution
- the ICs were rotated such that 2 pins (Vref and Gnd) are bonded to their nets. The loose Vz pin was connected via wire to its proper proper net.
- modifications of the PCB layout is pending
Wrong voltage on RC/RD junction
Description
A voltage of 2.75 V was measured on the junction between RC and RD resistors, instead of 2.25
Cause
Resistors RC and RD (2.5 kΩ and 2.0 kΩ respectively) have been reversed. The is an error on the layout: the placement designation and the silk-screen labeling is wrong.
Solution
- The resistors have been swapped.
- modifications of the PCB layout is pending
FET switch compatibility
Description
The FET switch BF1108 was not available in our market. Only its mirror package variant BF1108R could be procured.
Solution
- Temporary solution: The adaptation of the board for the BF1108R is shown in the adjacent figure. The IC is positioned in the shown orientation and its pins (pads) linked as shown.
- modifications of the PCB layout is pending