1) Bleed all lines prior to this process.
  −
 
  −
2) Turn on HV supply (turn key to on position) and allow the thyratron to warm up for at least ten minutes.
  −
 
  −
3) Evacuate the laser cavity until the fine gauge reads in the red (zero) by turning on the vacuum pump switch located on the laser head
  −
 
  −
4) Fill the system with 150mbar fluorine and 1850 He making the total pressure 2000mbar.
  −
 
  −
5) Set the Rep. Rate to 10Hz and turn on the HV supply (push button in)
  −
 
  −
6) Turn laser on (push button in) and set High Voltage to 20kV.
  −
 
  −
7) Laser will begin to pulse a red light, allow the laser to fire until the red light's intensity is reduced to about half. For the first few runs it may be necessary to re-fill a few times. The light should last AT LEAST 10 minutes.
  −
 
  −