|The average of the 64 measurements of Scintillating fibers was 2.00035 mm, with a standard deviation of 0.01814 mm. The average of the 64 measurements of the Light Guides was 1.99184 mm with a standard deviation of 0.01596 mm. 85.94% of the SciFi measurements were within one standard deviation of the mean, and 95.31% were within two standard deviations. 71.88% of the Light Guide measurements were within one standard deviation of the mean, and 98.44% were within two standard deviations of the mean.
+
The average of the 64 measurements of Scintillating fibers was 2.00035 mm, with a standard deviation of 0.01814 mm. The average of the 64 measurements of the Light Guides was 1.99184 mm with a standard deviation of 0.01596 mm. 85.94% of the SciFi measurements were within one standard deviation of the mean, and 95.31% were within two standard deviations. 71.88% of the Light Guide measurements were within one standard deviation of the mean, and 98.44% were within two standard deviations of the mean.
       
[[File:Average_Widths_Fusing.png]]
 
[[File:Average_Widths_Fusing.png]]
 +
 +
The average of the 38 measurements of fusing sites was 2.05139mm, with a standard deviation of 0.04706 mm. 73.68% of the measurements were within one standard deviation and 97.37% of the measurements were within two standard deviations.
    