2. Follow the diagram above and create a hardware approach to cold junction compensation.  After determining the voltage output of a type J thermocouple at zero degrees Celsius, I can introduce that voltage at the cold junction site.  By following the circuit above, I would probably be able to construct a circuit that would have cold junction compensation and amplification for the signal.  My concerns for this approach involve time constraints and the intricacies of this setup.
 
2. Follow the diagram above and create a hardware approach to cold junction compensation.  After determining the voltage output of a type J thermocouple at zero degrees Celsius, I can introduce that voltage at the cold junction site.  By following the circuit above, I would probably be able to construct a circuit that would have cold junction compensation and amplification for the signal.  My concerns for this approach involve time constraints and the intricacies of this setup.
 +
 +
Although, after having found this, I think the problem may be solved. 
 +
 +
[[media:Thermocouple_op_amp.pdf|Op amp designed for a type J thermocouple, with cold junction compensation]]
    