Difference between revisions of "Pratt/optics rail"
Jump to navigation
Jump to search
| (4 intermediate revisions by the same user not shown) | |||
| Line 2: | Line 2: | ||
{| cellpadding="3" style="text-align:center; margin: 1em auto 1em auto" | {| cellpadding="3" style="text-align:center; margin: 1em auto 1em auto" | ||
|- | |- | ||
| − | | [[File:long_view_rail.jpg|right|thumb]] || || [[File:Brendan-optics.jpg|left|thumb]]|| ||[[File:Stage_lens_sensor.jpg|right | + | | [[File:long_view_rail.jpg|right|thumb]] || || [[File:Brendan-optics.jpg|left|thumb]]|| ||[[File:Stage_lens_sensor.jpg|right|thumb]] |
|- | |- | ||
|} | |} | ||
| − | |||
| − | |||
{| cellpadding="3" style="text-align:center; margin: 1em auto 1em auto" | {| cellpadding="3" style="text-align:center; margin: 1em auto 1em auto" | ||
|- | |- | ||
| − | | [[File: | + | | [[File:optics-laser.jpg|left|thumb]] || || [[File:optics_laser_scope.jpg|left|thumb]] || || [[File:Longview_oscilloscope.jpg|left|thumb]] |
| + | |- | ||
| + | |} | ||
| + | *These photos are taken from a TurboCAD rendering of the optics rail that I completed this week. I have also added the 0.5cm x 0.5cm x 100 micron thick diamond at the optimum focal length ([http://zeus.phys.uconn.edu/wiki/index.php/Diamond_Radiator_Thinning_Using_an_Excimer_Laser#Updates_for_April_2010 17cm]) and tilted at a 45 degree angle from the beam axis. The blue cone represents the ablation plume and its dimensions are taken from plume characteristics observed in local thin film ablation laboratories. | ||
| + | {| cellpadding="3" style="text-align:center; margin: 1em auto 1em auto" | ||
| + | |- | ||
| + | | [[File:opticsE.jpg|right|thumb]] || || [[File:opticsC.jpg|left|thumb]]|| ||[[File:opticsD.jpg|right|thumb]] | ||
| + | |- | ||
| + | |} | ||
| + | {| cellpadding="3" style="text-align:center; margin: 1em auto 1em auto" | ||
| + | |- | ||
| + | | [[File:optics.BlastTCW.jpg|left|thumb]] || || [[File:rail.jpg|left|thumb]] || || [[File:blastII.jpg|left|thumb]] || || [[File:diamond_blast.jpg|left|thumb]] | ||
|- | |- | ||
|} | |} | ||
Latest revision as of 20:09, 7 May 2010
- This page is for the use of Dr. Richard T. Jones to display the progress made with the laser ablation optics system.
- These photos are taken from a TurboCAD rendering of the optics rail that I completed this week. I have also added the 0.5cm x 0.5cm x 100 micron thick diamond at the optimum focal length (17cm) and tilted at a 45 degree angle from the beam axis. The blue cone represents the ablation plume and its dimensions are taken from plume characteristics observed in local thin film ablation laboratories.