7/24: I measured bundle 401 on the popsicle stick. Bundle positions 16 to 30 are 6.81 mm wide including the Kapton. Measuring at positions 1 to 15, the bundle is 12.43 mm wide including the Kapton. The bundle is around 10 mm high, as it should be.
 
7/24: I measured bundle 401 on the popsicle stick. Bundle positions 16 to 30 are 6.81 mm wide including the Kapton. Measuring at positions 1 to 15, the bundle is 12.43 mm wide including the Kapton. The bundle is around 10 mm high, as it should be.
 +
 +
When I put bundle 401 in the dark box, I noticed a strip of paper between the fibers and the Kapton. That might have affected the width measurements.
 +
 +
7/25: Because the tests on bundle 401 after fusing were significantly lower than before fusing, I inspected the fibers whose transmission dropped the most. I did not see any signs of damage or poor fuse quality, however.
 +
 +
7/30: For answering the questions from Richard and Jim, see the All Tests sheet in 401 Stage 2 Tests 1.