Hall D Tagging Spectrometer and Photon Beamline Review Charge

 

January 23-24, 2006

 

 

The scope of this review is the Hall D coherent bremsstrahlung beamline, including the photon tagging system.  You are asked to address the following questions:

 

1.  Is the conceptual design of the tagger magnet and hodoscope systems reasonable and

     adequate to achieve the Hall D physics goals?

 

2.  Have the design parameters of the complete photon beamline been optimized for maximum

     physics impact?  For example, will this design achieve maximal linear polarization up to the

     highest envisioned rates?  Are the beamline diagnostics adequate?

 

3.  Are the specifications for the incident electron beam sufficiently well-defined, reasonable,

     and consistent with achieving the Hall D physics goals?

 

Please note that the Hall D detector, electronics, and data acquisition systems have been reviewed previously and these are therefore not the focus of this review.  You will be supplied with the reports from these earlier reviews along with your briefing materials.